Quick Overview

Programmable, Burst Mode, inline plug-in

$30.00

Out of stock

145158

Details

The Swiss Arms Burst MOSFET is an inline, plug in circuit board with programmable fire modes, including pre-set and user configurable burst fire modes. 

On the Swiss Arms programmable burst fire MOSFET, the user can set a custom burst mode from 2-12 rounds. Additionally, the MOSFET features 4 modes for 11.1v, 7.4v Lipo, and 8.4v or 9.6v NiMH. Selecting the correct mode delivers improved burst function and extended battery life.

Swiss Arms Burst Fire MOSFET Features:

-Easy inline plugin
-No wiring required
-Compatible with 7.4v-11.1v Lipo and NiMH

Operation Instructions:

MODE 1 selection (11.1v):

Step 1 - Long press the button on the Mosfet for 5 seconds till the LED lights up and then release the button. The light will remain lit up for 5 seconds.

Step 2 - You must Short press 1 time (while the LED is still on) and the light will blink 1 time signaling now it is on MODE 1.

Step 3 - To finish your selection of MODE 1, you need to Long press the button for 5 seconds, till the light go off on the Mosfet, signaling the MODE 1 selection is complete.

Note: If you forget which MODE you configured or you want to double confirm you are in the right MODE, simply short press the button to see how many times the LED light blinks on your Mosfet, after the Step 3 has been completed.

 MODE 2 selection (7.4v):

Step 1 - Long press the button on the Mosfet for 5 seconds till the LED lights up and then release the button. The light will remain lit up for 5 seconds..

Step 2 - You must Short press 1 time (while the LED is still on) and the light will blink 1 time.

Step 3 - Short press 1 more time and the light will blink 2 times signaling now it is on MODE 2.

Step 4 - To finish your selection of MODE 2, you need to Long press the button for 5 seconds, till the light go off on the Mosfet, signaling the MODE 2 selection is complete.

Note: If you forget which MODE you configured or you want to double confirm you are in the right MODE, simply short press the button to see how many times the LED light blinks on your Mosfet, after the Step 3 has been completed.

 

MODE 3 selection (8.4v):

Step 1 - Long press the button on the Mosfet for 5 seconds till the LED lights up and then release the button. The light will remain lit up for 5 seconds.

Step 2 - You must Short press 1 time (while the LED is still on) and the light will blink 1 time.

Step 3 - Short press 1 more time and the light will blink 2 times.

Step 4 - Short press 1 more time and the light will blink 3 times signaling now it is on MODE 3.

Step 5 - To finish your selection of MODE 3, you need to Long press the button for 5 seconds, till the light go off on the Mosfet, signaling the MODE 3 selection is complete.

Note: If you forget which MODE you configured or you want to double confirm you are in the right MODE, simply short press the button to see how many times the LED light blinks on your Mosfet, after the Step 3 has been completed.

 

MODE 4 selection (9.6v):

Step 1 - Long press the button on the Mosfet for 5 seconds till the LED lights up and then release the button. The light will remain lit up for 5 seconds.

Step 2 - You must Short press 1 time (while the LED is still on) and the light will blink 1 time.

Step 3 - Short press 1 more time and the light will blink 2 times.

Step 4 - Short press 1 more time and the light will blink 3 times.

Step 5 - Short press 1 more time and the light will blink 4 times, signaling now it is on MODE 4.

Step 5 - To finish your selection of MODE 4, you need to Long press the button for 5 seconds, till the light go off on the Mosfet, signaling the MODE 4 selection is complete.

Note  ** If by mistake you short press the button 1 more time after step 5 above, the light will blink 1 time signaling it has gone back step 2, so you need to repeat the step 3, 4, 5 again to arrive at MODE 4 selection.

Note: If you forget which MODE you configured or you want to double confirm you are in the right MODE, simply short press the button to see how many times the LED light blinks on your Mosfet, after the Step 3 has been completed.

The MODE selection will remain on same MODE configured, even if you disconnect the battery from your Mosfet.

Caution:

Please select the correct MODE to prolong the life of your battery.

Some things to note:

If you disconnect the Mosfet from your battery, it will still remember the shooting configuration of upto less than 15 shots.

Over 15 shots, it will default to 1 shot.

After selection of the mode then you can program your mosfet.


After connection of mosfet, Pull the trigger and keep it held down.
After 5 seconds you will hear a beep, beep, beep sound.
Pull the trigger according to how many shots you want + 1.
So if you want a 5 shot burst pull the trigger 6 times and keep it pressed on the sixth shot.
You will then hear a beep, beep, beep sound.
Your mosfet is now programmed.


Hi voltage lipo batteries may offset your program by 1-2 shots as the motor is running very fast.

0 Review(s)
 

Unmatched quality and service!

Founded in 2004, Airsoft Outlet Northwest (AONW) is the leader in quality airsoft and tactical gear in the Pacific Northwest. We're dedicated to providing the best service and products for our customers! We believe in honest and fair treatment of our customers while delivering superior value at a reasonable cost. That's why we offer the best warranty in the industry by providing in house warranty service on many quality brands like Classic Army, G&G, TopTech, and Echo-1. If you buy from us then you can rest assured knowing that you'll be taken care of.